worldinoutRegisterLogin | Set Homepage | Save desktop | Mobile | Qr code
Member
Shenzhen Artel Technology Co., Ltd.
Electrical Calibrators;Energy Meter Calibration;Power Meter Calibration
 
Your current location:Home » Sell » 300ms 0 ~ 600V 0 ~ 20mA PRO U31/32/33 AC Voltage Electrical Transducer, GB/T ...

300ms 0 ~ 600V 0 ~ 20mA PRO U31/32/33 AC Voltage Electrical Transducer, GB/T 13850-1998

Click image to view full size image
Title: 300ms 0 ~ 600V 0 ~ 20mA PRO U31/32/33 AC Voltage Electrical Transducer, GB/T 13850-1998 
Brand: -
Model: -
Unit price: Negotiable
MOQ: -0 -
Quantity: Negotiable
Delivery date: Since the payment date Days delivery

Contact: Miss. Maple (Ms.)    
Mobile:
Telephone:

  Inquiry
Details

 

300ms 0 ~ 600V 0 ~ 20mA PRO U31/32/33 AC Voltage Electrical Transducer, GB/T 13850-1998

 

1. Product Description

 

Pro Series Transducers for Electrical Quantities, fundamental devices for process automation. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safe isolation (IEC688-1992 standard and GB/T 13850-1998 standard). The devices have been developed, manufactured and tested in accordance with Quality Assurance System ISO 9001.

 

 

2. Technical Specification

 

Accuracy: Class0.2, 0.5    

Auxiliary Power Supply: 85V~265VDC/AC 24V~80VDC/AC  

Stability: Annual Change Rate ≤±0.2%

Input Overload Capacity:                     

Continuous Overload Capacity ≤1.5 X 

Transient Overload Capacity  Voltage Limit≤3X  Current Limit≤30X  

Output:

Constant Voltage Output, Load Resistor    Rext≥250Ω

Constant Current Output, Load Resistor    Rext≤500Ω

Alternating Wave: ≤18mV(Peak-Peak)  

Response Time: ≤300ms

Striking Voltage: ≤2.5kV

Operating Temperature: -10~+55

Storage Temperature: -40~+85

Relative Humidity of Annual Mean: ≤90%RH

Installation: DIN 35mm Rail

Size: 35mm×69mm×110mm 

Guaranty Period: 2 years

 

 

3. Technical Data

 

Input: 0~100V/0~120V/0~220V/0~380V/0~500V/0~600V

Output: 4~20mA, 4~20mA(2-wire),0~20mA,0~10mA,0~1mA,0~5V,0~10V,0-1V

 

 

4. Wiring

 

 PRO U31 Wiring Diagram

 

“OUT”  Output In Correspondence

“IN”    Input Current  Variables

“UH”    Auxiliary Power Supply

 

Note: 2-wire transducer just can select 24VDC auxiliary power supply and 4-20mA output signal.

               PRO U32 2in1 Wiring Diagram

 

UA, UC :   Input Voltage Variables

UH:            Auxiliary Power Supply

OA+, OC+: &
300ms 0 ~ 600V 0 ~ 20mA PRO U31/32/33 AC Voltage Electrical Transducer, GB/T 13850-1998

Inquiry
Sell
  • No Category
New Login
Company QR code
Anytime Anywhere Mobile